1
Wiring harness N1-1, N1-16 L, N
1
Wiring harness N1-1, N1-16 Bus
1
Wiring harness 1N1-16, 2N1-16 L, N
1
Wiring harness 1N1-16, 2N1-16 Bus
1
Wiring harness 1N1-16, X3-4
1
Connecting wire, brown 90 mm
1
Terminal strip, 6-pole, blue
1
Terminal strip, 8-pole, orange / grey
1
Holding bracket for electronic unit
2
Fixing plate for holding bracket for electronic unit
6
Raised-head screw CEM 6 x 12
1
Wiring diagram
Danger due to incorrectly carried out service and repair work
WARNING
Danger due to incorrectly carried out service and repair work
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
A
Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
A
All appropriate safety regulations must be taken into account.
A
First read the Technical Service Documentation (TSD), then commence work.
Risk of injury due to sharp edges
CAUTION
There may be a risk of injury due to sharp edges.
Risk of injury due to sharp edges!
A
Protective gloves should be worn and the edge protection, Mat. no. 05057680, should be used.
Install Module 7 for the flow meter first.
A
Remove the machine lid. See the model-related TSD.
A
Secure module (1) with electronic board holders (2) onto the traverse, see Fig. 1.
A
Fit terminal strips (3) in the pre-punched holes on the traverse. See Fig. 1.
A
Connect coding plug MFM 1-4-5 to ST3 on the module. See Fig. 2.
A
Connect screw connector strip to ST12 on the module. See Fig. 2.
The power (L, N) and control (bus) wiring harnesses must be laid separately in order to avoid interference in the
control circuit (electromagnetic compatibility).
Excess cable should be gathered so that current flows in opposite directions and tied to avoid any antenna effect.
A
Lay and connect wiring harness N1-16_X3-4. See Fig. 2.
A
Lay and connect wiring harness N1-1, N1-16 L, N. See Fig. 2.
A
Lay and connect wiring harness N1-1, N1-16 Bus. See Fig. 2.
A
Connect the flow meter connections in accordance with the wiring diagram.
A
Refit the machine lid.
A
Log the module on. See Service mode in the model-related TSD.
16.03.2018