en
Parts required
Quantity
Mat. no.
1
07738640
or
1
07738650
Note
This service and repair work should only be carried out by a suitably qualified electrician (with specialist training,
knowledge and experience, and recent related work experience) in accordance with all appropriate local and national
safety regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance
with all appropriate legal requirements, accident prevention regulations and valid standards. All regulations of the
appropriate utility supply companies and standards relating to safety (not limited to electrical safety) are to be complied
with.
Danger!
Even with the machine switched off, mains voltage may be applied to some components.
Before any service work is commenced, the machine must be disconnected from the mains. Suitable measurements must
be made to ensure that this is the case.
A general visual check should always be carried out.
Incorrect conversion or service work can be dangerous (risk of fire, electric shock, etc.).
Danger!
Correct earthing function can be deactivated if casing parts are incorrectly assembled.
Correct earthing function must be ensured when refitting the casing.
Carry out appropriate electrical safety checks.
Note
The conversion kit Mat. no. 07738640 for PT 8251 - PT 8333, PT 8501 - PT 8503 contains the following:
The conversion kit Mat. no. 07738650 for PT 8401 - PT 8403, PT 8801 - PT 8803 contains the following:
1 wiring harness 55X-K1/81-K1/73-X3
1 relay K1/81
1 relay 2K1/73
1 relay holder
3 raised-head screws 4 x 10
1 connection wire, brown, AWG 20 x 90
1 cable holder 200 x 4.8
1 cable screw connector M20 x 1.5
1 nut M20 x 1.5
Fitting instructions - Module BSS 19/20 - Peak-load cut-out, Mat. no. 07724460
List of illustrations:
Fig 1: Fitting relay and cable screw connector
16.06.2010
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
Designation
Conversion kit BSS 19 - Peak-load cut-out - PT 8251 - PT 8333,
PT 8501 - PT 8503
Conversion kit BSS 20 - Peak-load cut-out - PT 8401 - PT 8403,
PT 8801 - PT 8803
M.-Nr. 07724460

Publicidad

loading

Este manual también es adecuado para:

Bss 20