OPERATION MANUAL AND INSTRUCTIONS
ISTRUZIONI PER L'USO
SANDER SAFETY
- Periodically check that the sander and the power and compressed air supply cable are free from defects.
- Do not use the sander if damaged.
- Do not modify the sander. This can reduce the effectiveness of safety measures and increase operator risk.
- Connect the power supply cable to the mains socket, checking that the mains voltage matches the voltage stated on the plate
of the sander. (See TECHNICAL DATA table).
- To dissipate electrostatic charges, connect the earth to a cable with a section of at least 16 mm
- Electrostatic charges may accumulate while operating the sander. Avoid wearing shoes with Para rubber soles, synthetic
clothing or metal objects.
- Do not place the sander on insulating footboards (no pallets or rubber sheets). Antistatic footboards and antistatic bracelets
may be used.
- Unplug the sander when not in use.
- Do not use the sander in humid or wet environments; do not expose it to rain. Wet and contaminated environments increase
the risk of electric shocks.
PERSONAL PROTECTIVE EQUIPMENT TO WEAR WHILE OPERATING SANDER
Failure to observe the following warnings may result in physical injury and/or disease.
ALWAYS WEAR PROTECTIVE GLOVES AGAINST PHYSICAL AGENTS
ALWAYS WEAR EYE PROTECTION
ALWAYS WEAR SAFETY SHOES
ALWAYS WEAR PROTECTIVE CLOTHING
Additional personal protective equipment to wear according to the values found in the environmental
hygiene/risk analysis survey if the values exceed the limits under current regulations.
WEAR PROTECTIVE MASK AGAINST PHYSICAL AGENTS
TECHNICAL DATA
NOMINAL POWER SUPPLY VOLTAGE
AIR INLET
OPERATING PRESSURE
MINIMUM INTERNAL HOSE SIZE (Ø)
MEAN AIR CONSUMPTION
WEIGHT
OUTSIDE DIMENSIONS
PRODUCT LOADING CAPACITY
8
.
2
220V - 50Hz
Air hose Ø 8x6
6 bar
6.0 mm
340 l/min
38 kg
660x530x500 mm
ca. 10 kg
EN
I