Accuracy (Cont'd)
Resistance
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
Accuracy (cont'd)
6.000 MΩ
60.00 MΩ
All Models (cont'd)
Open Circuit Voltage: 0.45 VDC typical
AC Current
Range (50 Hz to 400 Hz)
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
10.00 A
*
8.00 A*
10A
10A to 20A
* 8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
DC Current
Range
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
10.00 A
8.00 A*
*
10A
10A to 20A
* 8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
Frequency —Hz (Line) at ACV, DCV, Current, AutoCheck™ Mode
Function
6 V
60 V
600 V
1000 V
600 µA
6000 µA
60 mA
600 mA
6 A
10 A
Accuracy
± (0.5% + 0.4 Ω)
± (0.5% + 0.004 kΩ)
± (0.5% + 0.04 kΩ)
± (0.5% + 0.4k Ω)
± (0.7% + 0.004 MΩ)
± (1.2% + 0.04 MΩ)
Accuracy
± (1.0% + 0.3 µA)
± (1.0% + 3 µA)
± (1.0% + 0.03 mA)
± (1.0% + 0.3 mA)
± (1.2% + 0.006 A)
± (1.8% + 0.006 A)
Accuracy
± (0.5% +0.5 µA)
± (0.5% + 3 µA)
± (0.5% + 0.05 mA)
± (0.5% + 0.3 mA)
± (1.2% + 0.006 A)
± (1.8% + 0.006 A)
Sensitivity (Sine RMS)
0.4 V
4 V
40 V
400 V
40 µA
400 µA
4 mA
40 mA
1 A
6 A
15
Diode Test
Measuring Range: 1.000 V
Test Current (typical): 0.56 mA
Open Circuit Voltage: < 1.8 VDC
Accuracy: ± (1.0% + 0.003 V)
Continuity
Tone Threshold: Between 10 Ω and 80 Ω
Response Time: < 32 ms
Burden Voltage (typical)
Burden Voltage (typical)
MM200A
0.1 mV/µA
1.7 mV/mA
17
0.03 V/A
0.1 mV/µA
1.7 mV/mA
0.03 V/A
Range
10 Hz to 10 kHz
10 Hz to 50 kHz
10 Hz to 50 kHz
45 Hz to 1 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz