TROUBLESHOOTING
Issue
After installation, the unit
doesn't work.
Light works, but motor is
not turning.
The unit is vibrating.
The motor is working,
but the lights are not.
The hood is not venting
out properly.
Metal filter is vibrating.
Cause
1. The power source is not turned ON.
2. The power line and the cable locking
connector is not connecting properly.
1. The blower is defective, possibly
seized.
2. Damaged capacitor.
1. The blower is not secure in place.
2. Damaged blower wheel.
3. The hood is not secured in place.
1. Defective halogen bulb.
1. The hood might be hanging to high from
the cook top.
2. The wind from the opened windows or
opened doors in the surrounding area
are affecting the ventilation of the hood.
3. Blockage in the duct opening or duct
work.
4. The direction of duct opening is against
the wind.
5. Using the wrong size of ducting.
1. Spring clip is broken.
2. Metal filter is loose.
What to do
1. Call for service.
2. Call for service.
1. Call for service.
2. Call for service.
1. Tighten the blower in place.
2. Change the blower.
3. Check the installation of the hood.
1. Change the halogen bulb.
1. Adjust the distance between the range
and the bottom of the hood to within
26"~34".
2. Close all windows and doors to eliminate
the outside wind flow.
3. Remove all the blocking from the duct
work or duct opening.
4. Adjust the duct opening direction.
5. Change the ducting to at least 6" or
higher.
1. Verify spring clip is not broken.
2. Replace the metal filter.