ENGLISH
Congratulations on your new radiator
from LVI!
CEB =
Radiator for wall mounting,. Electronic thermostat.
Delivered with 4-wire cable and junction box, plus
wall brackets and screws.
Rated voltage 230V alt. 400V.
IP 44.
CEB-P = Radiator for wall mounting, or for freestanding
positioning. Electronic thermostat. Supplied with
connecting cable provided with earthed plug, wall
brackets and screws.
Rated voltage 230V.
IP 44.
Installation
Mounting
Fig. 1. The supplied wall brackets are mounted on wall with
enclosed screws.The brackets are ideally placed approx. 100-
150 mm in from each end of the radiator.The brackets can be
used to mark out the height.
Fig. 2, 3. Note! The specified minimum measurements to
floor, window sill and side wall must be observed.The measure-
ment in fig. 3 between floor and lower attachment hole gives a
distance of 100 mm between the floor and lower edge of the
radiator. It is important for the function of the radiator that it is
mounted level.
Fig. 4. The wall upper end of the brackets can be pulled up
and locked in their top position to simplify the mounting of the
radiator. Make sure when locking the radiator in the brackets
that the upper part of the brackets properly grip the edge of
the radiator.
Fig 5. Model CEB-P can alternatively be provided with feet for
freestanding positioning.The feet are fitted by pressing them on
the radiator as shown in the fig.
The radiator is reversible.The thermostat housing should always
be at the bottom, closest to the floor.The radiator must not
be placed immediately under a wall socket or in the immediate
nearness of a bath, shower or swimming pool.
Connection of model CEB 230V alt. 400V
Fig. 6. The radiator's 4-wire cable is connected in the supplied
terminal box, which is ideally placed on the wall behind the
radiator.
Make sure that the terminal box is not touching the back of the
radiator.
The 4-wire cable is connected as follows:
Voltage:
230V (Fig. 6a)
Brown wire: (1)
Phase
Blue wire: (2)
Neutral wire
Black wire: (4)
Output controlled
phase. Used for
"master/slave"
connection.
Green/yellow. wire:
Earth
(3)
Connection of model CEB-P
The radiator's connecting cable with earthed plug is connected
to an existing wall socket. For permanent connection via a wall
terminal box, remove the plug from the cable and connect to
suitable wall terminal box.The terminal box is ideally placed on
the wall behind the radiator. Make sure that the terminal box
does not touch the back of the radiator.
Suitable terminal boxes are E 14 376 00, E 14 377 00 etc.
The 3-wire cable is connected as follows:
Brown wire: (1)
Blue wire: (2)
Green/yellow. wire: (3)
How to use
Fig. 7. The radiator is switched on by setting the switch in
position I, see fig. 7a.The required room temperature is set with
the thermostat dial, see fig. 7b.The green lamp goes on when
the radiator is emitting heat, see fig. 7c. If the set temperature
does not correspond to the achieved room temperature, the
thermostat can be adjusted. By pressing the adjusting buttons,
see fig 7e, the setting is changed by 0.5°C each time they are
pushed. Pushing the + button increases the setting, and pushing
the - button reduces the setting.The red lamp flashes each time
the button is pressed, see fig. 7d.
If an error is made, and/or to return to the default setting, push
both buttons in at the same time for approx. 3 seconds.
Fig. 8. The radiator is provided with a lockable panel. It can be
locked by moving the catch as per fig. 8.
Fig. 9. The radiator is provided with an overheating protector,
which disconnects the power if it becomes too hot, e.g. if
covered, or if the freestanding version has been tipped over on
its side.To reset, push in the reset button in the hole under the
LVI plate on the thermostat housing, see fig. 9. If disconnection
takes place repeatedly, check that no parts of the radiator are
covered. Otherwise contact your supplier.
Maintenance
When cleaning or wiping, only use mild detergent.
Miscellaneous
"Do not cover" means that the radiator must not be used for
drying clothes etc. by placing them directly on it.This radiator is
filled with a precise amount of special oil, and therefore repairs
that need it to be opened must only be carried out by the
manufacturer or their service representative. In the event of
leakage, contact your supplier or their representative.
This radiator has a special connecting cable. If it is damaged and
needs replacing, it must be ordered from the manufacturer or
their representative.
The connecting cable for model CEB has LVI part no.
641 09 01. Connecting cable with plug for model CEB-P has LVI
part no. 642 10 01.
Accessories
Grille and side plates, feet for model CEB-P, and lock device for
400V (Fig. 6a)
locking the upper part of the radiator brackets are available as
Phase 1
accessories.
Phase 2
Contact your supplier for further information.
Output controlled
phase 1. Used for
Warranty
"master/slave"
The warranty is valid for 5 years. In the event of any problems
connection.
or repairs, please contact your supplier.
Earth
Phase
Neutral wire
Earth