Mounting options (1) with clamping levers and (2) with clamping screws
Maintenance and inspection of the magnetic clamp
Regular maintenance and inspections are necessary to ensure the safe use of the switchable magnetic clamp.
Furthermore, country-specific standards and regulations must be observed depending on application.
The maintenance intervals are classified according to the recommended schedule.
Before every use...
visually inspect the magnet for damage
clean the surface of the workpiece and the underside of the magnet
free the underside of the magnet of rust, chips or unevenness
Weekly...
inspect the magnetic clamp for deformation, cracks or other defects
make sure the activation lever is working properly and latches correctly into place
inspect the bottom of the magnet for scratches, pressure points or cracks and have the magnet repaired by
the manufacturer if necessary
Monthly...
check the markings and labelling on the magnet for legibility and damage and replace them if necessary
Annually...
have the load-bearing capacity of the magnet checked by the supplier or an authorized workshop, should
the application so require
Unauthorized repairs or modification to the magnetic clamp are not permitted.
If you have any questions, contact the manufacturer.