is installed in the appliance, the control signal
must be connected to the control terminals
„DC A1/Z1 (positive terminal) and DC A2/Z2
(negative terminal)" which are covered over
at the factory (ensure that polarity is correct).
The 230 V AC control signal must not
be connected to the „DC+ (A1/Z1)
and DC- (A2/Z2)" terminals, since this
would destroy the charging regulator.
Operation and fault display (V4) on
the electronic charging regulator
LED lights up „green"
No faults
the charging regulator is working perfectly.
⇒ Fault
LED lights up „red"
a)
Selector switch for charging (R1) and/or
remote sensor (B1) is defective or not
connected.
Plug-in bridge X17 for charge reduction
b)
is missing.
No charging will take place.
⇒ Fault
LED lights up „orange"
(only with discharge regulator fitted):
a)
Internal discharge regulator (A2)
defective.
b)
Room temperature sensor (B2)
defective or not connected.
No discharging will take place.
c) Selector switch for discharge (R2) is
defective or not connected.
The room temperature is regulated to
about 22 ºC.
Microfuse 5x20mm 2Amps. slow
The electronic charge controller is fitted with
a replaceable fuse in the circuit to provide
additional protection.
The fuse is located in a two piece fuse holder
between the X1 and X2 connections.
To access the fuse, the upper section of the
fuse holder must be removed from its base.
Before changing the fuse the
electrical supply to the appliance
must be switched off.

2.3 Regulations and provisions

Take careful note of the enclosure leaflet in
the appliance and accessory pack.
The building and garage regulations of the
country concerned are to be respected.
The surface on which the appliance is set
up must have a sufficient load-carrying
capacity.
In case of doubt, a structural surveyor is to
be consulted (see „Technical Data" for the
weights of the storage heaters).
20
The minimum interval distances to
adjacent surfaces are to maintained
All electrical connection and installation
work is to be carried out in accordance
with VDE specifications (0100), the
instructions issued by the particular
electricity utility company concerned, and
the relevant national and regional regulations.
The appliance must be capable of being
isolated at all poles from the mains
network by means of an additional device
with a circuit sever of at least 3 mm. To do
this, contactors, fuses, and similar elements
may be used.
Any subsequent increase to the connected
load must have repeat approval from the
electricity utility company concerned. If
subsequent increase in connected load is
not notified to the utility company, this will
constitute a breach of the power supply
contracts.
The operating media are to be designed to
match the rated consumption of the
appliance.
The appliance type rating plate is to be
observed carefully. The voltage indicated
must accord with the mains voltage.
The appliance must be secured in order to
fulfil the VDE (Association of German
Electrical Engineers) requirements for
stability.

2.4 Place of installation

The appliance must not:
– Be operated in areas which are subject
to the risk of fire or explosion due to
chemicals, dust, gases or vapours;
– Be operated in the immediate vicinity of
pipes or containers which carry or
contain combustible or potentially explo-
sive substances;
– Be operated, at less as the minimum
clearance distances advised.
In workshops or other areas in which the
odour of waste gases, oil, petrol, etc. might
occur, or in which work is carried out
involving solvents and chemicals, there is a
risk of sustained odour burdens being eng-
endered, and possibly of dirt contamination
occurring.
Installation wall
A check must be made as to whether an
adequately load-bearing securing wall is
available for securing the appliance.
If no suitable securing wall is available, the
device must be secured to the floor (bolted
directly to the floor or secured by means of a
Vario bracket [special accessory]).
Floor
The surface on which the appliance is to be set
up must be even and of sufficient load-bearing
capacity for the housing not to be moved.
It must be ensured that the securing
wall has a temperature resistance of
at least 85 ºC, and the floor of at least 80 ºC.

2.5 Appliance installation

B.
In order to accord with the VDE requirement
for stability, the heat storage device must be
secured by a wall or floor securing element
H.
The screws and dowels required for securing
the appliance do not form part of the scope
of supply. They are to be selected and
obtained by a qualified installer on the basis
of the material of which the wall is
constructed.
Securing to the wall
A hole is to be provided in the rear wall of
the appliance, in the area of the switching
elements, through which a suitable load-
bearing screw or bolt is inserted for the
purpose of securing it (for dimensions see
„Technical Data", page 18).
Before securing the appliance, care is to be
taken to ensure that the permissible
minimum distance intervals to adjacent
surfaces are maintained.
Securing to the floor
The appliance is secured to the floor by
screwing or bolting the base of the appliance to
the floor through 4 holes of 9 mm diameter.
This securing arrangement can only be
carried out if the air outlet and inlet grilles
and the air flow device are removed.

2.5.1 Installation of heater

Unscrew the air outlet grille (5) and take
it out, together with the air intake grille (6);
Unscrew the front wall (4) and the
front wall (8) located behind
case at the lower edge, pivot it forwards,
and detach it at the upper edge by raising
it slightly;
Raise the right-hand side wall element (3)
slightly and take it off;
Guide the mains connection leads and
connection leads for the charging and
discharging regulator through the
aperture in the rear wall of the appliance
(15) into the device, and connect it, taking
Point 2.5.2 into account (offset the
connection lead by about 260 mm and
shorten it as required, in such a way that
it cannot touch the slots in the side panel);
Place the appliance at the intended
installation location and screw or bolt it to
the securing wall (with the base securing
to the floor as required).
Remove the cover plate (10) and the
cardboard inserts from the interior. These
must be entirely free of foreign bodies
such as packing residue, etc.
Check the thermal insulation in the
appliance for transport damage, and
replace it if necessary.
Insert storage blocks
The storage blocks can be used even with
slight transport damage. This will not impair
the operation of the appliance.
To insert the storage blocks (9), the heating