CODE
18
Extension cord is wrong length or gauge
20
Possible defective motor or starting capacitor
POSSIBLE CAUSE
i POSSIBLE SOLUTION:
'Drain oiJ and refill pumP with DEWALT synthetic compressor
0il,
Check for proper gauge wire and cord length. See
Extension
Cords under Installation.
COntact a DEWALT factory service Center
a DEWALT
authorized service center.
Contact
a DEWALT factory service center or a DEWALT
authorized service center.
21
Paint spiay 0n internal motor parts
Contact
a DEWALT faCt0rY Seivice Centei
a DEWALT
I
auth0rized Service Center. Do not operate the compressor in
•
the paint spray area. See flammaMe vapor warning.
22
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
I
23
Tank pressure exceeds pressure switch cut-in pressure
24
Pressure release valve on pressure switch has not
unloaded head pressure
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
i
i Motor will start automatically
when tank pressure drops
below cut-in pressure of pressure switch!
Set the On/Off switch to OFE If the valve does not open,
replace switch. Contact a DEWALT factory service center or
a DEWALT authorized service center.
19