Close all open recesses on the cover (62) with blank covers (63).
22
63
Version with lighting
Observe the ESD-regulations!
The cover is delivered with pre-mounted sensor electronics.
The plugs of the control panels on the sensor PCB can be in-
serted in any sequence. Fix the cables to the clamping bow.
63
22
23
The lighting is supplied with power via the TEB-3 fan or a
separate cable.
If the device S 3004 / S 3004 P / S 5004 is operated without
the TEB-3 fan, a separate 12 V cable needs to be fitted for the
lighting (Art.-No. 30090-38100) from the fused onboard power
supply (alternating current ripple <1.2 Vss).
S 3004 P only
Connect the flat plug on the ignition cable (16) and the mass
cable (15) to the Piezo push ignitor (18). Push the earth ca-
ble (15) through the recess in the support and insert into the
right (R) or left (L) earth contact of the installation box.
15
16
18
51
0
1
5
4
2
3
50
62
63
0
1
2
3
62
18
16
15
L
R
Place the cover (62) on the support (60) and click in. Make
sure that the cables are laid without any bends and are not
jammed.
Place the control knob (51 – gas) on the control rod (7) so that
the marking points to the "0" position.
22
63
23
Fig. B
Clip in the sign (65) to the mica window cover (left for right
installation and right for left installation).
Attach cover
51
Suspend the cover (1) in the bottom bearing and pivot in (2)
until the lock audibly clicks into place. Check the tight fit by
pulling.
50
5
4
1
62
63
0
1
2
3
60
7
2
51
50
5
4
19