Technical Data - Beninca CP.B24ESA Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36

TECHNICAL DATA

Contol unit power supply
Power supply
Output
Maximum current:
Accessories power supply
Protection level
Operating temp.
Radio receiver
Memory capacity
Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
L/N
Power supply
Primary
L1/N1
Transformer
Secondary
0V/MOT/AUX
Transformer
MOT
Motor
ENC
Encoder
COM
SWO
Limit Switches
SWC
SAFETY
BAR/BAR
EDGE
PED
PEDESTRIAN
Open
PHO
Photocell
PHC
Photocell
STOP
STOP
P.P.
Step by step
+COM
COMMON
SHIELD/ANT
antenna
+ 24V -
24 Vdcs
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1 motor 24Vdc
CP.B24ESA: 2.8 A - CP.B1024ESA: 3.5 A
24Vdc 500mA max.
CP.B24ESA:IP30 - CP.B1024ESA:IP20
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code+ ARC
Advanced Rolling Code)
64 rolling-code transmitters
CONTROL PANEL CP.B24 ESA / CP.B1024 ESA
WIRE DIAGRAM
Description
Input, 230VAC 50/60 Hz (L-Phase/N-Neutral) CP:B24ESA/CP-B1024ESA
Input, 115VAC 50/60 Hz (L-Phase/N-Neutral) CP:B24ESA/CP-B1024ESA-A
Connector for the connection of the primary transformer
L1: Line
N1: Neutral
Connector for the connection of the secondary transformer
CP.B24ESA:
0V: 0V Input - MOT:23 VAC - AUX:18 VAC
CP.B1024ESA: 0V: 0V Input - MOT:30 VAC - AUX:18 VAC
Fast connector for motor connection
Fast connector for encoder connection
Rapid connector for the connection of limit switches.
COM:Common for limit switches
SWO:Input, OPEN limit switch (N.C. contact)
SWC:Input, CLOSE limit switch (N.C. contact)
Input: sensitive safety edge
8K2 resistive safety edge: closed "DAS" jumper
Mechanical safety edge: open "DAS" jumper
When the safety edge is activated, the gate leaf stops and its movement is reversed for around
3 seconds.
Pedestrian push-button intput (N.O. contact). The gate partial opening is controlled
according to the value preset by the TPED parameter.
It is activated only with totally closed gate.
With OPCL:ON or HTR:ON, it becomes "CLOSE" input.
Input, photocell activated in both opening and closing phases
Input, photocell is activated in the closing phase.
STOP button input (N.C. contact)
Input, Step-by-Step push-button (Normally Open contact)
If the logics is OPCL=ON or HTR=ON, the OPEN input function is provided.
If the logics HTR is ON, it is FORBIDDEN to use the input with timers or other similar
systems.
Common for all control inputs.
Connection antenna to the built-in receiver
SHIELD: Screen / ANT: Signal
Accessories power supply 24Vdc/500mA max.
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp.b1024esa

Tabla de contenido