TECHNICAL DATA
Mains power supply
Output, Motor
Motor max current
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
CAUTION!: The CP.BISON OTI control unit is equipped with an embedded anti-crash device (amperometric
sensor). Given the overall dimensions of the door leaves for which the device is intended, the latter cannot
be considered a safety device. It is therefore STRICTRLY mANDATORY to install activated protection sen-
sitive edges according to regulations in force.
N° Terminals
Function
1-2-3-4
Power supply
5-6-7-8
INVERTER
9-10
Flashing light
24V Flashing
15-16
light or Phototest
17-18
SCA
19-20
24 VAC
SERIAL 485
Serial, inverter
Encoder
Encoder
21-22
Antenna
23-36
COM
24
SWC
25
SWO
26
PHOT 1
27
PHOT 2
28
PHOT 3
29
PHOT 4
30
STOP
31
OPEN
32
CLOSE
33
PED
34
Step-by-Step
35
AUX IN
35
N/A
37-38
SAFETY
16
Single-phase: (BISON 25 OTI) 230 VAC 50/60 Hz
Three-phase: (BISON 30/45 OTI) 400 VAC 50/60 Hz
1 motor, 230 V three-phase or 400 VAC three-phase
BISON 25 OTI: 8A - BISON 40 OTI 2.6 A
24VAC 0.4 A max.
IP54
-20°C / +50°C
433,92 MHz, incorporated and configurable
(rolling-code or fixed+rolling-code+ ARC Advanced Rolling Code)
64
CP.BISON OTI CONTROL UNIT
INPUT/OUTPUT FUNCTIONS
Description
Single-phase or three-phase mains power supply.
The unit is powered through a mains filter applied before the control unit.
Single-phase 1: Phase - 2: Neutral – 3: Not in use - 4: GND
Three-phase 1:L1 - 2:L2 - 3:L3 - 4:GND.
Single-phase or three-phase INVERTER connection
Single-phase 6: Phase – 7: NEUTRAL
Three-phase 5:GND - 6:R - 7:S - 8:T.
Connection of flashing light, 230VAC 40W max, or 115VAC 40W max, for BISON TI 115.
Connection to 24VAC flashing light or Phototest output for checked photocells.
Normally open, voltage-fee contact for open gate indicator light, 24VAC 0.5A max
Output, power supply of accessories, 24Vac/400mA max
485 serial communication between control logics and Inverter.
Connection to motor Encoder.
Connection to built-in radio receiver module of the antenna (21-signal/22-monitor).
Common, for all control inputs.
Input, CLOSE limit switch (Normally Closed contact)
Input, OPEN limit switch (Normally Closed contact)
Input, Limit switch 1 (NC contact). It can be disconnected in the opening phase, see PH01 logics.
Input, Limit switch 2 (NC contact). It can be disconnected in the opening phase, see PH02 logics.
Input, Limit switch 3 (NC contact). It can be disconnected in the opening phase, see PH03 logics.
Input, Limit switch 4(NC contact). It can be disconnected in the opening phase, see PH04 logics.
Input, STOP push-button (Normally Closed contact)
Input, push-button for OPEN contact (Normally Open contact)
Input, CLOSE push-button (Normally Open contact)
Input, push-button for pedestrian opening (Normally Open contact)
Input, Step-by-Step push-button (Normally Open contact)
Input for Dead man function
By connecting this output to 36-COM terminal,
To be used by means an appropriately marked N.O. contact for controlling the automation
even in case of encoder failure.
Not in use
Input, sensitive safety edge. When the safety edge is activated, the door movement is stopped
and reversed (see SPIN Parametters).
Safety edge of the resistive type: Jumper "DAS" closed.
Safety edge of the mechanical type: Jumper "DAS" open.
dead man function is enabled.