Operating Instructions
Installation (Continued)
LUBRICATION
THIS UNIT CONTAINS OIL. Before operating
compressor, check oil level (see Figure 7).
Using any other type of oil may shorten pump
life and result in damage.
Recommended Oil
Single viscosity ISO46 rotary screw compressor oil (Part
number CS0030 - 1 Gallon Container). Available from Campbell
Hausfeld, please call 1-855-504-5678 for customer assistance.
Oil Capacity
1.5 gallons
OIL LEVEL
Disconnect, tag and lock out
power source then release all
pressure from the system before attempting to install,
service, relocate or perform any maintenance.
RISK OF BURNS! The unit parts,
oil, and screw plug can be hotter
than 175° F (80° C)! Wear personal safety equipment!
Power Indicator
(WHITE)
ON / OFF Switch
[Lighted when in
ON position
(GREEN)]
Figure 8 - Control Panel
12
www.campbellhausfeld.com
Figure 7 - Oil Level
With hot oil, the oil level can be approximately
3/4 inch higher than with cold oil shortly after
discharging.
An important factor for the operating safety of the compressor
system is the oil level in the oil reservoir. The oil level check must
be performed before initial operation of the compressor and then
repeated every 100 operating hours.
Oil Plug
Maximum (cold oil level)
Minimum (cold oil level)
E-Stop
High Temperature /
High Pressure
Indicator Light
and Reset (RED)
Hour Meter