EN
2. DC Application
- DC terminals are only for charging
12V battery;
- Concerning the automatic type
battery with the leads, be sure to
disconnect the negative leads of the
battery while charging.
Connect the positive
CAUTION:
and negative poles of the battery
with the positive and negative poles
of DC terminals separately. Do not
confuse them, otherwise the battery
and generating set will burn out;
Do not connect the positive pole of
the battery with its negative pole,
other-wise the battery damage will
result;
Type
Incandescent
Lamp
Heating
Appliance
Fluorescent
Lamp
Motor driven
x 3~5
Equipment
VIII. STOP THE GENERATOR
- Disconnect the load from the
generator.
- Turn off the air switch of the
generator.
- Let the generator work without
load for about 1 minutes.
- Do not stop the engine suddenly,
otherwise the generator will be
damaged.
- Concerning the electric starter,
turn the key to "OFF".
28
Do not connect the positive pole of
the DC terminal with its negative
pole, otherwise the generator will
be damaged;
When a large capacity battery is
charged, excessive current flows,
the fuse for the direct current will
burn out.
Do not run the generator while it is
still connected with the battery.
Do not use DC12V and AC at the
same time.
Power (w)
Typical Electrical
Start
Rated
Incandescent
x 1
x 1
x 2
x 1.5
x 2
WARNING:
running even after the speed lever
is placed at the "STOP" position,
either turn the fuel cock to the
"CLOSE" position or loosen the nut
of high pressure fuel pipe on the
pump side to stop the engine.
Do not stop the engine with the
decompression lever.
Appliance
Electrical Appliance
Incandescent
Lamp
TV
Fluorescent
Fluorescent
Lamp
Fridge
If the engine keep on
3. Dimensioning
Electrical Appliance particularly
motor-driven equipments will produce
very High current while starting, the
bellow table provides the reference
for connecting these apparatus to the
generator.
Example
Start
100 VA
Lamp
(W)
100 W
Lamp
80VA (W)
40 W
Fan
450-750
150 W
VA (W)
F14
Rated
100 VA
(W)
60VA (W)
300 VA
(W)