9.
Assembly of Shower Panel (2-part Function Block)
9.1
Remove the stainless steel housing or open the glass front.
☞
For further details please consult the Installation and Operating Instructions for the
fitting.
9.2
Use a hollow hexagon wrench to close the water volume regulators.
a: closed
b: open
9.3
Trigger the valve.
Spare parts
9.4
Disconnect the line connection between the solenoid valve cartridge and the
electronic module.
9.5
Remove the screws (c).
9.6
Remove the solenoid-valve cartridge (d).
9.7
Use a flat nose pliers to pull the existing filter (e) out.
9.8
Continue with
Retrofitting thermal disinfection
9.9
Remove the screws (f).
9.10 Unscrew the plug (g).
☞
Use an M8 screw to pull out the plug via the centre thread.
9.11 Insert the new filter.
☞
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
9.12 Insert the solenoid-valve cartridge.
9.13 Tighten the screws.
9.14 Connect the line connection between the solenoid-valve cartridge and the electronic
module (k).
l: Solenoid-valve cartridge mixed water
m: Solenoid-valve cartridge bypass, thermal disinfection
☞
Insert an adapter (n) if necessary.
9.15 Mount the stainless steel housing or close the glass front.