Setting the Clock
When the pump is first plugged in, the clock will blink to
indicate that is has not been set. Any daily schedule set
by the user will be based on this clock setting, so it will
be necessary to set the clock first.
To Set the Clock:
1. Press and hold the Display button for 3 seconds.
2. Use the "+" and "-" arrows to choose between a 12
or 24 hour time format.
3. Press Display to advance in the Clock Setup menu
4. Use the "+" and "-" arrows to change the time to the
correct time of day. In the 12 hour time format AM/
PM will display in the bottom right corner.
5. Press Display to advance.
6. Use the "+" and "-" arrows to adjust the screen
backlight brightness.
7. Press Display to exit the Clock Setup menu. The
clock is now set.
During a power outage, the drive will retain the clock
setting in memory for as long as 24 hours. If the power
is out longer than 24 hours the clock will have to be set
again. If the drive has lost the user set time, the clock
will continuously blink until the time is reset. Once the
time is reset the clock will stop blinking.
Note: When power is returned to the pump after a
prolonged outage (24+ hours) the clock will automatically
set itself to the Speed 1 start time, blink and advance.
The pump will also run the associated schedule from that
start time.
OPERATING THE PUMP
Using the Default Schedule
The default schedule is designed to provide enough daily
turnover to service a typical pool. See Table 2 for default
schedule.
Duration
(Hours)
SPEED 1
SPEED 2
SPEED 3
Table 2: Default Schedule.
SPEED 1 is set to begin at 8:00am and run at 3000 RPM
for a duration of 2 hours. When SPEED 1 is complete
the pump immediately begins running the default SPEED
2. SPEED 2 is factory default to 1400 RPM and will last
for 10 hours. When SPEED 2 has completed its run the
pump will run SPEED 3 at 2200 RPM for a duration of
two hours.
After 14 hours of run time and completing its run of
SPEED 3, the pump will enter a stationary/paused state
for the next 10 hours. The pump will restart at 8:00am
the next morning and cycle through the default schedule
again. The pump will continue to run in this in this
manner until a custom schedule is programmed into the
drive by the user.
Note: The Start/Stop button must be pressed, and the
LED lit, for the pump to run.
SUPERMAX
VS Variable Speed Pump Installation and User' s Guide
®
Speed
(RPM)
2
3000
10
1400
2
2200
7