CODE
POSSIBLE CAUSE
24
Fuse blown, circuit breaker tripped
25
Tank pressure exceeds pressure switch cut-in pressure
26
Pressure release valve on pressure switch has not
unloaded head pressure
POSSIBLE SOLUTION
1. Check fuse box for blown fuse and replace as
necessary. Reset circuit breaker. Do not use a fuse or
circuit breaker with higher rating than that specified
for your particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper
extension cord.
4. Disconnect the other electrical appliances from circuit
or operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a D
or a D
WALT authorized service center.
e
24
WALT factory service center
e