To avoid voltage drops in the electrical cables, cables with appropriate sections should be used according to their length.
The spotlight cable should never be changed. The supplied cable guarantees a sealing degree of IPX8. The use of a
different cable could cause a loss in sealing leading to the breakdown of the spotlight.
· Joint connection
A single link cable can be used to help in connecting the feeder with the spotlights.
For this connection method, cables with appropriate sections should be used according to their length.
6. CONTROL SYSTEMS OF THE LED PROJECTORS:
Installations with Mini LED spotlights only, can be controlled from the feeder itself. In installations where there are also
Colorplus spotlights, the feeder can synchronize these spotlights with the Mini LED spotlights.
6.1. Control through the feeder
The feeder is provided with a pushbutton, which is the simplest way of controlling the spotlights. Each press changes the
colour or sequence.
The pushbutton is normally closed (NC). It is connected in the terminals indicated "pushbutton input" shown in figure 9.
With this control system you have 14 function modes: 7 fixed colours and 7 sequences with different colours.
6.1.1. Diagram of the electrical connection
Length (m)
0-20
20-30
30-50
Length (m)
0-20
20-30
30-50
-4-
Cable section
1.5 mm2 Cu
2.5 mm2 Cu
4 mm2 Cu
Cable section
2.5 mm2 Cu
4 mm2 Cu
6 mm2 Cu