5.

INSTALLATION INSTRUCTIONS

Components necessary for installing a D-BOLT on concrete. Required fasteners for the installation are not supplied
with the product, the following components are also required:
§
hammer drill
§
concrete drill (please observe the information in the fixtures' assembly instructions)
§
blow-out pumps for drill hole cleaning (Würth item no. 0903 990 001)
§
cleaning brushes (Würth Art. No. 0905 499 007)
§
calibrated torque spanner with articulated head size 24
§
hammer
§
WÜRTH Injection System W-VIZ/A4 M16 consisting of:
1x anchor rod
1X adhesive cartridge
or
WÜRTH Injection System W-VIZ-IG/A4 M16 consisting of:(SKYLOTEC item no. AP-057 without
adhesive cartridge)
1x anchor rod
1x Hexagon screw
1X washer
1X adhesive cartridge
Special note:
The minimum strength class of concrete must be C20/C25 and the concrete must have a minimum thickness of
170 mm when fastening using the Würth injection system W-VIZ/A4 M16 and 160 mm with the Würth injection system
W-VIZ-IG/A4 M16x120.
5.1 SKYLOTEC D-BOLT AP-058, AP-063-GE and AP-063-GPS anchor point
in installed condition using WÜRTH injection system W-VIZ/A4 M16
All dimensions in mm.
MAT-MA-0005-00-GB
W-VIZ/A4 M16-125-30/180
WIT-VM 100 330ml (incl. Static mixer)
W-VIZ-IG/A4 115 M16x 120
M16 x 45 DIN 933 V4A 70
Di=17, Da=30, T=3 DIN 125 V4A
WIT-VM 100 330ml (incl. Static mixer)
D-BOLT
20.07.2018
(WÜRTH item no. 0905 451 601)
(WÜRTH item no. 0905 440 003)
(WÜRTH item no. 5916216120)
(WÜRTH item no. 0905 440 003)
3
Number of users :
.
.
N
= N
Ɣ
= (6+2) kN
F,d
F,k
F
All directions
Ɣ
F
Page 4 of 19