Operating Condition - Leister UNIFLOOR E Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Operation
Operational condition: Accessories
If the welding rod de-reeler (24) and lifting device (26) are available:
– Attach welding rod de-reeler (24) to the Unifloor E tool using cheese
head screw M8 × 20 (25).
– Attach lifting device (26) to the tool using socket head cap screw M6 × 30 (27).
Accessories
Welding rod de-reeler
25

Operating condition

• Check the nozzle setting: the nozzle must be positioned at a distance of about 2-3 mm from the floor cover and
welding rod.
• When welding linoleum, lower the cover (28) on to the welding nozzle (4) (see Detail A).
Detail A
Cover
open
• Automatic drive
Automatic drive is adjusted as required, depending on nozzle position, by means of switch pin (22) and
set screw (23).
• Connect tool to the mains. Mains voltage must correspond with the voltage rating stated on the tool.
• Switch on tool using main switch (14). Hot air blower (3) starts automatically.
• Important: under voltage
If the maximum temperature is not reached, reduce the airflow by means of the manual air vane (11) and
potentiometer for air flow (17).
12
24
4
28
Accessories
Lifting device
Cover
closed
4
26
27
28
13

Publicidad

Tabla de contenido
loading