6.2.3 Sound pulse display
Switch
3
4
↑OFF
↓ON
Switch
7
8
9
↑OFF ↑OFF ↑OFF
ON ↑OFF ↑OFF
ON ↑OFF
↑OFF
ON
ON ↑OFF
ON
↑OFF ↑OFF
ON ↑OFF
ON
ON
ON
↑OFF
ON
ON
ON
6.2.4 Permanent light
Switch
3
4
↓ON
↓ON
Switch
7
8
9
↑OFF ↑OFF ↑OFF
ON ↑OFF ↑OFF
ON ↑OFF
↑OFF
ON
ON ↑OFF
ON
↑OFF ↑OFF
ON ↑OFF
ON
ON
ON
↑OFF
ON
ON
ON
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
Operating mode
sound pulse display
Effect variant
random order of variants
green running light against
a red background
white running light against
a green background
white running light against
a blue background
blue running light against
a dark background
bars in red|yellow|green
bars with changing colours,
different on several units
bars with changing colours,
identical on several units
Operating mode
permanent light
Colour
white
red
green
yellow
blue
purple
cyan
white
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
6.3 Execution speed
Via the DIP switches No. 5 and No. 6, the speed for the
execution of the effects can be adjusted in four steps.
Switch
5
6
↑OFF
↑OFF
ON
↑OFF
ON
↑OFF
ON
ON
6.4 Running direction
Via DIP switch No. 10, the direction of the running light
effects and of the sound pulse display can be adjusted.
Switch
10
↑OFF
↓ON
7 Specifications
Power supply: . . . . . . . . 230 V~/50 Hz
Power consumption: . . . 30 VA
Light source: . . . . . . . . . 144 super bright LEDs
Ambient temperature: . . 0 – 40 °C
Dimensions. . . . . . . . . . 1000 × 100 mm × 65 mm
Weight: . . . . . . . . . . . . . 1.6 kg
Subject to technical modification.
Execution speed
low
high
Running direction
(48 each in red, green, blue)