UK
Troubleshooting
Fault
Appliance not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Appliance does
Faulty thermostat
not reach set
Faulty element
temperature
Build-up of fat on the element
Appliance heats up
Indicator light has expired
but indicator light
does not come on
Power indicator
Faulty element
light comes on but
appliance does not
Faulty thermostat
heat up
Thermostat set incorrectly
Appliance slow to
Faulty element
heat up
Build-up of fat on the element
No power
Thermal cut-out activated
Technical Specifications
Model
Voltage
FC374
230V, 50Hz
FC375
230V, 50Hz
FC376
230V, 50Hz
FC377
230V, 50Hz
6
FC374-FC375-FC376-FC377_ML_A5_v2 20200318.indb 6
Probable Cause
Capacity
Power
(litres)
2900W
8L
2 x 2900W
2 x 8L
6000W
8L
2 x 6000W
2 x 8L
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Clean the appliance
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Check thermostat
Call BUFFALO agent or qualified technician
Clean the appliance
Press re-set switch on rear of unit
Max batch
Dimensions
load (kg)
H x W x D mm
1
450 x 280 x 510
2 x 1
450 x 560 x 510
1
450 x 280 x 510
2 x 1
450 x 560 x 510
Weight
11.1kg
19.6kg
12.2kg
22.3kg
2020/3/18 17:09