Note: Failure to clean the appliance regularly may result in premature activation
of the thermal cut-out switch.
•
Remove the head unit for ease of cleaning.
•
Empty the oil to clean the appliance thoroughly.
Warning: Do not remove the oil pan until AFTER it has been emptied.
•
If the oil is to be reused then filtering it before refilling will extend the oil's cooking life.
•
Use a suitable detergent to clean the interior of the appliance.
•
Use warm, soapy water and a damp cloth to clean the exterior of the appliance.
•
Dry thoroughly after cleaning, ensure there is no water left in the fryer.
•
A BUFFALO dealer or qualified technician should carry out repairs if required.
Troubleshooting
Fault
Appliance not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Thermal cut-out activated
Safety switch not located
properly
Appliance does
Faulty thermostat
not reach set
Faulty element
temperature
Build-up of fat on the element
Appliance heats up
Indicator light has expired
but indicator light
does not come on
Power indicator
Faulty element
light comes on but
Faulty thermostat
appliance does not
heat up
Thermostat set incorrectly
Appliance slow to
Faulty element
heat up
Build-up of fat on the element
6
FC255_DB203_FC256_FC257_ML_A5_v2 20200312.indb 6
Probable Cause
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Reset thermal cut-out
Refit head unit
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Clean the appliance
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Check thermostat
Call BUFFALO agent or qualified technician
Clean the appliance
Solution