6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be pre-
sent for installations in closed housings.
The air intake on the underside or the air outlet on the back of the device
must remain clear.
The installation surface must be level and sufficiently sturdy.
➤ Secure the mains rectifier with the fastening bracket (fig. 2, page 3).
7
Using the mains rectifier
A
NOTICE!
Do not reverse the polarity. If the poles are reversed device
may overheat and be damaged.
Replace defective fuses with new ones of the same rating
(12 A slow-blow).
➤ Fit wire sleeves to the ends of wires which you wish to connect to the
mains rectifier.
I
NOTE
To avoid drops in voltage and therefore performance, keep the
cable route as short as possible and only disconnect it when
necessary.
EN
Mounting the mains rectifier
19