Capítulo 2
Instalación y configuración
Level 2
Level 3
Overall Wiring Status
Volt Input Missing
Volt Input Inverted
Amps Input Missing
Amps Input Inverted
Voltage Rotation
Amps Rotation
Volts Ph1 Angle
Volts Ph1 Magnitude
Volts Ph2 Angle
Volts Ph2 Magnitude
Volts Ph3 Angle
Volts Ph3 Magnitude
Amps Ph1 Angle
Amps Ph1 Magnitude
Amps Ph2 Angle
Amps Ph2 Magnitude
Amps Ph3 Angle
Amps Ph3 Magnitude
Degrees Out Of Range
40
Figura 29 - Menú principal, página 2
Display Wiring
Display Run
Status
Status
Series Number
Catalog Number
Comm Type
WIN Number
Application FRN
Boot Code FRN
Default Device ID
Accuracy Class
Overall Status
Flash Memory
SRAM Memory
NVRAM Memory
SPI Interface
Real Time Clock
Watchdog Timer
Metering Status
LCD Interface
Serial Interface
Ethernet Interface
Input Over Range
Phase Loss Detection
Terminals Locked
Troubleshooting Mode -
Times Left
Figura 30 - Submenú de configuración
Level 2 Program Mode, Level 3 Display Mode
Analog
Input
Level 3, 4
Voltage Mode
PT Primary
PT Secondary
CT Primary
System PF Setting
Edición de parámetros
Para editar un parámetro, haga lo siguiente:
• Presione hacia <arriba> o hacia <abajo> para cambiar el dígito resaltado.
• Presione hacia <arriba> y hacia <abajo> a la vez para mover el cursor una
posición a la izquierda y presione <hacia arriba> o hacia <abajo> para
establecer el valor del dígito seleccionado.
Haga lo mismo hasta introducir el valor correcto y, a luego, presione <enter>
cuando haya terminado.
Publicación de Rockwell Automation 1408-UM002A-ES-P - Julio 2015
Display
Display I/O
Security
Status
Status
Date
Security Status
Time
KYZ Status
S1 Status
Status 1 Cnt
S2 Status
Status 2 Cnt
Output Word
Configuration Menu
Advanced
RS485
Setup
Setup
New Password
Protocol Setting
Set Date Year
Serial Delay ms
Set Date Month
Baud Rate
Set Date Day
Serial Address
Set Time Hour
Serial Data Format
Set Time Minute
Inter Character -
Set Time Second
Timeout
Meter Averaging
Maximum Node -
DST Enable
Address
DST Start-
Mth, Wk ,Day
DST Start Hour
DST End -
Mth, Wk, Day
DST End Hour
KYZ Output Select
KYZ Output Scale
KYZ Output Duration
Status 1 Input Scale
Status 2 Input Scale
Demand Source
Demand Length
Demand Periods
Demand Sync Delay
Unit Error Action
Error Log Full Action
LCD Contrast 3 to 40
Program
Commands
Clear kWh Registers
Clear kVARh Registers
Clear kVAh Registers
Clear Energy All Registers
Clear Status One Count
Clear Status Two Count
Force KYZ Relay On
Force KYZ Relay Off
Remove Force From KYZ
Restore Defaults
Perform Wiring Diagnostics
Reset System
Clear Min/Max Log
Store Load Factor Record
Clear Load Factor Log
Store TOU Record
Clear TOU Log
Clear Energy Log
Troubleshooting Password
Log Off
Ethernet
Security
Setup
Setup
IP Address Obtain
Hardware Config Lock
IP Address Byte A
Comm Port disable
IP Address Byte B
Web Page Disable
IP Address Byte C
FTP Port Disable
IP Address Byte D
Flash Update -
Subnet Mask Byte A
Config Lock
Subnet Mask Byte B
Flash Update -
Subnet Mask Byte C
Security Active
Subnet Mask Byte D
HTTPS Enable
Gateway Byte A
FTPS Enable
Gateway Byte B
Gateway Byte C
Gateway Byte D
SNTP Mode Select
SNTP Update Rate
SNTP Time Zone
SNTP Server Byte A
SNTP Server Byte B
SNTP Server Byte C
SNTP Server Byte D
Broadcast Mode
Broadcast Port
Program
Configuration
See Menu for
Configuration