Manual operation:
Mount the fl oating switch as illustrated in Fig. 1.
The equipment will then run continuously. To pre-
vent dry running, this operating mode is allowed
only under supervision. The equipment must be
switched off (pull out the power plug) as soon as
no more water is emitted from the discharge line.
Dirty water mode (Fig. 4/5):
Turn the equipment counter-clockwise up as
far as the stop (Fig. 4/5).
Shallow suction mode (Fig. 5):
Turn the equipment clockwise down as far as
the stop (Fig. 5).
In shallow suction mode, water can be su-
cked up down to a level of 1 mm.
Only clean water can be sucked up in shallow
suction mode.
Please note:
For the equipment to suck up water in shallow
suction mode there must be a minimum depth of
10 mm of water.

7. Replacing the power cable

Danger!
If the power cable for this equip-
ment is damaged, it must be
replaced by the manufacturer or
its after-sales service or similarly
trained personnel to avoid dan-
ger.
GB
8. Cleaning, maintenance and
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
8.1 Cleaning
8.2 Cleaning the intake cage and pump
1. Screw out the three screws (Fig. 6/Item B)
2. Turn the equipment up as far as the stop (Fig.
3. Clean the intake cage (Fig. 7/Item 4) and the
4. Assemble in reverse order.
5. When assembled, the lug must be in the cor-
8.3 Maintenance
There are no parts inside the equipment which
require additional maintenance.
8.4 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
For our latest prices and information please go to
www.isc-gmbh.info
www.sidirika-nikolaidi.gr
- 21 -
ordering of spare parts
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
housing (Fig. 5/6/7/8):
counter-clockwise.
5). Note the position of the lug (Fig. 5/Item A)
and remove the intake cage (Fig.7/Item 4).
pump impeller housing (Fig.7/Item C) with
clean water.
rect position (Fig. 8/Item A).
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ge-dp 5220 ll eco41.707.9041.707.80Ge-dp 7330 llGe-dp 5220 ll

Tabla de contenido