Siemens SITRANS LPS200 Manual Del Usuario página 6

Ocultar thumbs Ver también para SITRANS LPS200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mechanical
Process Connections
• threaded connection
• flanged connection
Enclosure
• construction
• conduit entry
• ingress protection
• vane and shaft construction
Weight
Standard temperature:
• compact
• extended
• angled extended
• cable
High temperature:
• compact
• extended
• angled extended
• cable
Environmental
• location
• altitude
• ambient temperature
• relative humidity
• Installation category
• Pollution degree
Process
Temperature
Standard model:
• –25 to +80 °C (–13 to +176 °F)
• CSA temperature code: T5
• maximum surface temperature
Page EN-4
SITRANS LPS200 – INSTRUCTION MANUAL
1", 1¼" , 1½" NPT or 1", 1¼" , 1½" BSP
material: stainless steel 303 (1.4305), optional
aluminum
DN 32 PN 6, DN 100 PN 6, DN 100 PN 16,
2", 3", 4" ASME, 150 lb, B 16.5 (1.4541/321)
epoxy coated aluminum
2 x M20 x 1.5, or
2 x ½" NPT
Type 4X/NEMA 4X/IP66
stainless steel 304 and 303 (1.4301 and 1.4305)
1.8 kg (4.0 lb)
2.2 kg (4.9 lb)
4.0 kg (8.8 lb)
3.2 kg (7.1 lb)
2.6 kg (5.7 lb)
3.0 kg (6.6 lb)
5.2 kg (11.4 lb)
4.0 kg (8.8 lb)
indoor/outdoor
max. 2000 m (6562 ft)
–25 to +60 °C (–13 to +140 °F)
0 to 100 %, suitable for outdoor (ingress
protection: Type 4X/NEMA 4X/IP66)
III
2
+120 ºC (+248 ºF) [ATEX relevant]
7ML19985FS62

Publicidad

Tabla de contenido
loading

Tabla de contenido