SERIOUS PERSONAL INJURY AND/OR DEATH MAY RESULT FROM USE OF THIS HEATER
IN AN UNVENTILATED BUILDING OR IN HUMAN LIVING AREAS.
Do not use the heater to heat human living areas. The intended use of the heater is to provide warmth
for poultry and hog buildings
Use only the type of gas being supplied to the unit as marked on it (Propane or Natural Gas). Do not
operate with improper fuel.
Before each use, a visual inspection of the heater is essential to insure safety and satisfactory heating.
Replace or repair defective components before operating heater. Failure to do so will void warranty and could
result in injury and property damage.
WARNING: Improper installation, adjustments, alteration, service or maintenance could cause property
damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
WARNING: Failure to follow WARNINGS in this manual could result in serious injury or significant
property damage.
Before lighting, sniff all around the appliance area for a gas odor. Be sure to sniff next to the floor
because propane gas is heavier than air and may temporarily exist at floor level.
DO NOT ALLOW POWER CORDS AND/OR GAS SUPPLY HOSES TO REST ON THER CANOPY, HANGING
BRACKETS OR OTHER HOT SURFACES OF THE UNIT OR TO COME WITHIN 12" OF THE HEATER.
DSI UNITS MUST BE PROPERLY GROUNDED. DO NOT ALTER ELECTRICAL CORD.
Plug in the three-prong power cord to a correctly grounded three-prong electrical outlet.
The installation of this appliance must in all cases conform with local and national building codes or in
the absence of local codes to the current National Fuel Gas Code ANSI Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Codes, CSA B149.1 and B149.2.
Heaters must be electrically grounded in accordance with the National Electrical Code, ANSI/NFPA 70
or the current Canadian Electrical ode, CSA C22.1. Polarity of Line voltage and neutral wires must be
maintained. The total load of all heaters in a circuit must be considered for overload control of that circuit.
Power supply must have earth ground.
THESE INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER TO RETAIN
READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, USING OR SERVICING THIS
For additional manuals or more information, see our website at
WARNING!
FOR FUTURE REFERENCE.
EQUIPMENT.
www.ctbinc.com
3