7.2 Maintenance
Figure 28
Cleaning the sieve tube in the quick closure valve: Unscrew the hose connection from
28
the quick closure valve and remove from the quick closure valve with the sieve. Unscrew
the sieve tube from the hose connection and wash thoroughly with water. Mount in
reverse sequence after cleaning. Hand-tighten all screw connections.
CAUTION
You may be exposed to hazards that could injure you when cleaning the sieve tube.
Wear safety gloves and protective clothing, if necessary.
Completely depressurise the hose line by pulling the actuation lever on the quick
closure valve, even if the device is empty, and dispose of any remaining liquid in the
system onto vegetation.
The sealing ring in the container cap and all other moving parts must be regularly greased
with resin- and acid-free grease.
Only use original GLORIA spare parts for repairs.
Repairs must be carried out by a GLORIA service point.
NOTE!
To ensure optimal cleaning of the spraying device, the use of the GLORlA spraying
device cleaner, Art. No. 1100.0000 is recommended.
7.3 Storage
Figures 29 - 30
Empty and clean the device as described in the chapters Emptying and Maintenance.
Loosen the container cap – Clip spraying lance onto the spraying lance holder –
29
30
Store the device without pressure and frost-free.
CAUTION
You may be exposed to hazards that could injure you when handling the device and the
pesticides. You must therefore store the device and the pesticides away from children.
8
Problems with the device
8.1 Troubleshooting
Fault
Device is leaking at the
screw connection
Spray pattern of nozzle not
OK
Cause
Hose loose
Nozzle partially blocked
24
Remedy
Tighten coupling nut and
carry out pressure test with
water
Clean filter or nozzle