Descargar Imprimir esta página

SDMO AT206 Manual De Uso página 54

Caja automática

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
6 – PROGRAMMING CONTROL UNIT AT206
6.1 – PROCEDURE FOR ACCESSING THE CODE AND DISPLAYING THE MAIN PARAMETERS (USER)
Accessing the code
Press the RESET button the TEST for 5 seconds
The screen shows SET.
Displaying the parameters
Press the MEAS button to change the parameter
Example: U0.1 → U0.2 → U.12
1. The screen displays "U0.1"
2. Press the MEAS button
3. The screen displays "U0.2"
4. Press the MEAS button
5. The screen displays "U0.3" etc.
This procedure enables inputs to be made in the "User" menu, allowing only the parameters for normal use of the card to be modified
and preventing access to the highly technical parameters which could cause operational problems for the control unit.
Access to the specialised menu is only possible if a different password is entered.
To obtain this password, please contact the manufacturer or retailer.
6.2 – PROCEDURE FOR MODIFYING THE MAIN PARAMETERS (USER)
Modification of the parameters
Press the TEST button to access the parameter value.
Example:
1. The screen displays "U0.8"
2. Press the TEST button
3. The value of the parameter appears on the screen "20"
4. Press the START button
5. The parameter value increases
6. The screen displays "21"
7. Press the STOP button
8. The parameter value decreases
9. The screen displays "20"
10. Press the STOP button again
11. The screen displays "19", etc.
12. Exit without confirming → Press AUT
13. Exit by confirming the modification → Press RESET.
14. To exit the parameter setting menu → Press AUT then RESET.
20 / 32

Publicidad

loading

Productos relacionados para SDMO AT206