General Information; External Unit; Art. 4878K; Art. 1207 - Comelit 4878K Manual Tecnico

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42

General information

The single-family door entry monitor kits Art. 8171IGK can be used in
residential or service sector buildings where effective access control and
simple installation procedures are required.
In fact, it only requires 2 wires between the external unit and the internal
monitor/s to activate the system (calls, audio, video self-ignition), plus two
wires to provide the 33 V DC power supply for the external unit and the
electric lock.
A wide range of accessories is also available to deal with the needs of any
type of system; in fact, in addition to interesting standard type accessories,
the system can also be extended by adding door entry monitors and/or
door-entry phones and/or external units.
This makes it possible to reach a maximum of 2 external units with 3 internal
units including door-entry phones and door entry monitors for single-family
configuration.
By means of appropriate settings single-family intercom communications
(i.e. between users with the same user code) are possible using both door
entry monitors and door-entry phones.
Several kits can be connected to a Simplebus main entrance panel and/or
a switchboard Art. 1998A.

External unit

Art. 4878K

Technical characteristics
Connection to monitor with 2 wires for audio, video, lock-release and call
plus 2 wires for power supply from Art. 1207.

Installing the external unit

Leave the system protec-
tion device in position
1
Nameplate LED lighting selection
WHITE
3
Art. 4878K
BLUE
OFF
Flush-mounted box dimensions: 127x127x45 mm.
The button for Art. 4878K is factory set to call address 1.
External unit dimensions: 112x89.5x40 mm
Description of terminal block
LL monitor connection (video, call, audio, lock-release)
V+ V- external unit power supply
RTE request to exit input
DO door open indication input
PR programming terminal
GND negative terminal to be used in programming stage
NO NC COM 10 A relay contacts
SE electric lock connection
Technical characteristics
The transformer provides 2 outputs: one to power the external unit and the
electric lock and the other to power the monitor.
Dimensions: 105x85x85 mm (6 DIN modules).
500 mA delayed protection fuse.
Description of terminal block
L
N mains voltage input 110-240 VAC
+22V 0V monitor power supply DC output
+33V 0V DC output for external unit and electric lock
2
4

Art. 1207

11
11

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

120758015814k2608

Tabla de contenido