NOTICE:
Do not operate the evaporative cooler without the filter
media while the pump is running. Doing so could damage
the motor and reduce performance.
 For better cooling, open the compartment door and place
ice in the water flow control compartment.
NOTE: Do not place ice directly over the water distribution
holes as this may obstruct the flow of water to the filter
media.
 Press the COOL button again to turn the pump off.
WARNING:
After turning the pump off, run the evaporative cooler
fan for 15 to 30 minutes to dry the filter media. Always
thoroughly dry the filter media to prevent the possible
formation of bacteria or mold. Circulating air through a
filter media that contains bacteria or mold can result in
serious personal injury or illness.
WARNING:
Always completely drain water tank when not in use
to prevent the possible formation of bacteria or mold.
Using a cooler that contains bacteria or mold can result
in serious personal injury or illness.
To adjust water flow from the pump:
The flow of water from the pump to the filter media can be
controlled by using the water flow control knob. For cooler
air, increase the flow of water. For warmer air, decrease the
flow.
 Turn the pump on as described earlier.
 Open the compartment door.
 Turn the water flow control knob counterclockwise to
increase the flow of water from the pump and clockwise
to decrease it.
 Close the compartment door.
OPERATION
Changing the distribution of air flow:
The distribution of air flow can be adjusted by changing
the position of the fan louvers. To change the direction of
horizontal airflow, adjust the vertical louvers:
 Press the SWING button on the control panel or remote
control to make the vertical louvers move from left to
right automatically. The swing icon ( ) will appear in the
digital display.
 Press the SWING button again to stop louver movement.
To change the direction of vertical airflow, manually adjust
the horizontal louvers.
Setting the timer:
The evaporative cooler can be set to function automatically
for intervals of 30 minutes up to 8 hours. To set the time for
the evaporative cooler:
 Press the TIMER button to cycle through the available
settings.
 The evaporative cooler will run until the allotted time has
expired.
LOW WATER ALERTS
As the evaporative cooler's pump is running, the amount of
water in the water tank will dissipate. When the water level
becomes low, the low water alert will beep and the low water
icon ( ) will flash in the digital display. If the water supply
becomes insufficient to operate the pump, the pump will
shut off automatically. The fan will continue to operate even
when the pump is off.
To resolve the low water alert, disconnect the evaporative
cooler from the power supply and fill the water tank as
described earlier. Then restart the unit and resume normal
operation.