overview | Side panel
1. AC input power Cord (See #1 on Fig. 1)
Provides power to your Battery Backup.
2. AC Breaker (Circuit Breaker; see #2 on Fig. 1)
Should a power overload occur, the circuit breaker triggers the Unit to turn
off AC power. To restore power, press the "circuit breaker" button to reset,
then press the "Power" button.
3. uSB Communication port (See #3 on Fig. 1)
The Unit features a USB communication port. Installation of the cable and the Bulldog Plus Software, which allows the Unit to connect
to your computer, is optional. The Unit will provide backup power whether or not the cable and software are installed; however, without
them you will be unable to utilize the data management product features.
overview | Alarms
Backup (Slow Alarm)
When the Unit is in "backup" mode (running on battery), the YELLOW LED illuminates and the Unit emits an audible alarm. The alarm
stops when the Unit returns to normal online operation.
low Battery (rapid Alarm)
In "backup" mode, when the battery energy runs low, the Unit beeps rapidly until it either shuts down from a depleted battery or
returns to normal online operation.
Fault (Continuous Alarm)
When the Unit fails, it emits an audible alarm continuously to warn of a fault condition. Disconnect the equipment prior to checking it.
overview | Storage
Storage Conditions
Store the Unit covered and upright in a cool, dry location with its battery fully charged. Before storing, charge the Unit for at least
twelve (12) hours.
Extended Storage
During extended storage in environments where the ambient temperature is -15 en +30 °C, charge the Unit's battery every six (6)
months. During extended storage in environments where the ambient temperature is +30 and 45 °C, charge the Unit's battery every
three (3) months.
Note:
overview | Technical Specifications
Model
Capacity
Input
Output
(inverter Mode)
Transfer Time
Battery
Display
Audible Alarm
Protection
Physical
Shucko
Environment
All specifications are subject to change without prior notice.
VA/W
Voltage
Frequency
Max input current
Phase
Voltage Range
Frequency
Max output current
Waveform
Typical
Battery Type
Backup Time at a PC load with monitor
(Typical 100W)
Recharging Time
LED
Battery Mode
Low Battery
Overload
Fault
Full Protection
Dimension (DxWxH)
Net Weight
France
Operation Temperature
Operation Humidity
F6H400ukUSB
F6H400exUSB
F6H400evUSB
400VA/200W
12V4.5Ahx1
6-11 Minutes
Overload, Overcharge, Modem/Phone Line Surge
Protection and Short Circuit Protection
UK
4 sockets for surge protection with battery backup
2- EN
F6H600ukUSB
F6H600exUSB
F6H600evUSB
600VA/300W
220/230/240VAC
50/60Hz
5A
Single
220/230/240VAC+10%
50Hz or 60Hz+1Hz
5A
Modified Sinwave
2-6ms
12V5Ahx1
10-15 Minutes
16 hours max
(recharge up to 90% capacity)
Power on, Backup, Fault
Sounding every 5 seconds
Sounding every second
Sounding every 0.5 second
Continuously Sounding
352mm*134mm*86mm
2.9KG
0-40
C
o
0-90%
3