So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
•
Never use the machine in potentially explosi-
ve areas under any circumstances!
•
The operating temperature must be between
+5 and + 40°C.
•
Do not cover or modify the lance or the spray
nozzles in any way.
•
The pressure cleaner is designed to be used
with cold or lukewarm water (max. 40 °C); hig-
her temperatures can damage the pump.
•
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
equipment.
Caution: Risk of explosion
Do not spray fl ammable liquids.
Warning
Water that has passed through the non-return
valve is not drinkable.
Warning
If cleaning agent gets into contact with your skin
or into your eye, rinse immediately with lots of
clean water. Then consult a doctor or follow the
steps described on the safety data sheet or provi-
ded by the manufacturer of the cleaning agent.
5.2 Assembly
5.2.1 Assembling the equipment (Fig. 1)
Push the accessories holder (2) onto the high-
pressure cleaner (5). The holder can be used for
space-saving storage of the gun (8), the extensi-
on (9) and the high-pressure hose (14).
Note! Before using the pressure cleaner, make
sure that the high-pressure hose is completely
unwound.
5.2.2 Fitting the attachments (Fig. 2)
Before you use the high-pressure cleaner (5) you
must fi rst fasten the extension (9) to the gun (8)
by pushing and twisting.
Then push the rotating nozzle (13) or the cleaning
agent container (10) onto the extension (9) by
means of the quick connection system.
Rotating nozzle
To remove particularly stubborn dirt, use the rota-
ting nozzle (13).
Anl_TC_HP_1334_SPK7.indb 18
Anl_TC_HP_1334_SPK7.indb 18
GB
Cleaning agent container
You can adjust the quantity of cleaning agent you
want to add by turning (+ / -) on the setting wheel
(11). We recommend using the cleaning agent
sparingly.
5.2.3 Connecting the high-pressure hose
(Fig. 3/4)
Connect the high-pressure hose (14) to the gun
(8) and the high-pressure cleaner (5).
Note:
The connections for the high-pressure hose
and the accessories are equipped with a quick
connection system (12). To connect, simply push
the hose or the accessory onto the respective
connection. To remove, simply actuate the quick
connection system (12) and you can remove the
hose or the accessory.
Each time before fi tting, always check that the
quick connection system (12) is correctly enga-
ged. Do this by pulling briefl y on the hose or the
accessory.
5.2.4 Water inlet connector (Fig. 1/4)
The connection for the water inlet (4) is equipped
with a connector for standard hose coupling sys-
tems. Plug the hose coupling on the supply hose
(min. Ø 1/2"/13 mm) to the water inlet connector
(4).
Always use a reinforced hose with a standard
coupling for the water inlet. The hose should be at
least 6 m in length. (Not supplied)
A backfl ow preventer must be installed between
the drinking water and the pressure cleaner! Ask
your local plumber about this.
5.2.5 Electrical connections (Fig. 1)
•
Before you connect the equipment to the
power supply make sure that the data on the
rating plate are identical to the supply voltage.
•
If you use any extension cables, make sure
that they are suitable for outdoor use and
have large enough wires:
1 – 10 m: 1.5 mm²
10-30m: 2.5 mm²
•
Insert the power plug on the power cable into
the socket outlet.
- 18 -
26.02.16 08:34
26.02.16 08:34