WARNING: Empty the tank (M) every time you finish using it.
CAUTION! Before removing the tank, switch off the appliance and unplug it.
Completely press the two buttons (U) located besides the handgrip (T)
Lift up the handgrip (T)
Lift up the handle (N) and remove the tank (M)
Turn the handle (N) over and pull the filter assembly (O) up/forward.
Check the solids filter (R) and remove any deposits. If steam or liquids have been vacuumed or of
filtration water has been used, rinse the internal part of the tank as well as the filter assembly com-
ponents with running water.
Check and eventually clean the microfibre filter (P)/ sponge filter (Q) with running water from the
inside out; let it dry before reassembling the filter assembly.
To make for easier cleaning of the internal part of the tank, regularly remove the internal baffle (Z)
: carefully unlock both ends of the internal baffle (Z), see picture. To put it back, wedge the
(picture 52)
baffle onto the edge of the tank by hooking the ends.
12 TOPPING UP THE BOILER WATER TANK WITH WATER
The boiler water tank (L) supplies the boiler
through an electronic level control; since this is an
external tank, it can be topped up any time.
When water runs out in the boiler water
tank:
1. the appliance beeps intermittently
2. the no-water level pilot light (G) flashes
3. the steam stops coming out.
EN

11 EMPTYING THE TANK

picture 48
picture 50
(picture 49-50)
(picture 51)
picture 49
picture 51
To top up, proceed as follows:
Switch off the boiler switch (E)
Turn off the main switch (D)
Remove the cable from the socket
Remove the boiler water tank cap (C)
Fill the boiler water tank (L)
Put on the boiler water tank cap (C)
picture 53