During the first start‐
up LEDs LD1 and LD3 
do not light up 
alternatively 
The device does not 
react to the call from 
an enabled number
The device cannot 
engage in the GSM 
network 
Technical Specification 
10.
GSM/GPRS module
GPRS 
output power 
power supply 
current 
relay outputs 
max. current relay contacts
digital inputs 
master users 
dimensions 
weight 
operating 
temperature 
Use this device with original accessories only. Velleman nv cannot be 
held responsible in the event of damage or injury resulted from 
(incorrect) use of this device. For more info concerning this product 
and the latest version of this user manual, please visit our website 
www.velleman.eu. The information in this manual is subject to 
change without prior notice. 
© COPYRIGHT NOTICE 
The copyright to this manual is owned by Velleman nv. All worldwide rights 
reserved. No part of this manual or may be copied, reproduced, translated or 
reduced to any electronic medium or otherwise without the prior written 
consent of the copyright holder.  
 
31.05.2011
HAMGSM133 
The device has already
been started 
The mobile used for 
the call has a hidden 
ID
The PIN on the SIM 
Card has not been 
disabled
SIM900 Quad (850/900/1800/1900MHz)
multi‐slot class
mobile station class
class 4
class 1
9 to 32 Vdc stabilized (or Li‐Ion battery 800~1000mAh 
(not incl.))
50mA (idle), 1A max.
2 (to control low tension loads), type SELV (<60Vdc)
2 (logic 1 = 5~32Vdc; logic 0 = 0Vdc
8
103 x 67 x 28mm (L x W x H)
±100g
‐10 ~ 55°C (14 ~ 131°F)
10/8
B
2W @ 850‐900MHz
1W @ 1800‐1900MHz
10A
10
Completely reset the 
device using the RES 
command. 
Enable sending caller 
ID on the used mobile 
phone
Disable the PIN 
request from the SIM 
Card
 
©Velleman nv

Publicidad