and use of the software. Download the (English) software from:
http://www.futurashop.it/download/Compilato_eng.zip
Configuration SMS
8.
Commands and settings can be sent from any mobile phone as long
•
as the message includes the password.
For some commands a password is not required when the message
•
was sent from a telephone number which is stored in the
HAMGSM133. However, some commands that change critical
information always require a password.
The HAMGSM133 replies with a confirmation or information SMS.
•
Multiple commands can be combined in 1 SMS by placing a comma
•
in between.
Note: commands never contain spaces.
Refer to overview of all configuration SMS commands below. The first
line contains the function followed by the default value and whether a
password is required; the second line shows the SMS command (bold).
password replacement
PWDxxxxx
store numbers (max. 8, max. 19 digits per number); x is the memory
position (only password required when position x is occupied)
NUMx+393359999999
delete a number
NUMx
check stored numbers
NUM?
full reset
RES
set numbers that will receive SMS
SMSxxxxxxxx:ON
set numbers that will receive ringtones
VOCxxxxxxxx:ON
logic level high alarm (input under tension); x = 1 or 2
LIVx:A
logic level low alarm (no tension on input); x = 1 or 2.
LIVx:b
31.05.2011
HAMGSM133
(default: 12345, password required)
(password required)
(password required)
(password required)
(default: all, password required)
(default: all, password required)
(default: active under tension)
(default: active if no tension)
7
©Velleman nv