Electrical safety
The electric motor has been designed for one voltage only.
Always check that the power supply corresponds to the
voltage on the rating plate.
Your Berner tool is double insulated in
accordance with EN 60745; therefore no earth
wire is required.
Mains plug replacement
(U.K. & Ireland only)
•
Should your mains plug need replacing and you are
competent to do this, proceed as instructed below. If
you are in doubt, contact an authorized Berner repair
agent or a qualifi ed electrician.
•
Disconnect the plug from the supply.
•
Cut off the plug and dispose of it safely; a plug with
bared copper conductors is dangerous if engaged in
a live socket outlet.
•
Only fi t 13 Amperes BS1363A approved plugs fi tted
with the correctly rated fuse (1).
•
The cable wire colours, or a letter, will be marked
at the connection points of most good quality plugs.
Attach the wires to their respective points in the plug
(see below). Brown is for Live (L) (2) and Blue is for
Neutral (N) (4).
•
Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the outer
sheath of the cable fi rmly and that the two leads are
correctly fi xed at the terminal screws. Never use
a light socket.
Never use a light socket.
Never connect the live (L) or neutral (N) wires
to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W, we
recommend to fi t a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this machine
(see technical data). The minimum conductor size is
1.5 mm². The cable has to have a rubber jacket and a
grounding conductor. When using a cable reel, always
unwind the cable completely. Also refer to the table below.
Conductor size (mm
0.75
1.00
1.50
2.50
4.00
Voltage Amperes
115
230
Assembly and adjustment
Mounting the saw blade (fi g. B)
•
•
•
•
Saw blades
material
ferrous metal
non ferrous metal
wood
.
plastic
masonry
A wide variety of dedicated saw blades is available as
an option.
Setting the adjustable saw shoe (fi g. C)
The saw shoe can be adjusted to limit the depth of cut
and prolong the life of your saw blade.
15
) Cable rating (Amperes)
2
6
10
15
20
25
7.5 15 25 30 45 60
Cable rating (Amperes)
0- 2.0
6
6
2.1 - 3.4
6
6
3.5 - 5.0
6
6
5.1 - 7.0
10 10 15 20 20 25
7.1 - 12.0
15 15 20 25 25 -
12.1 - 20.0
20 20 25 -
0 - 2.0
6
6
2.1 - 3.4
6
6
3.5 - 5.0
6
6
5.1 - 7.0
10 10 10 10 15 15
7.1 - 12.0
15 15 15 15 20 20
12.1 - 20.0
20 20 20 20 25 -
Prior to assembly and adjustment always
unplug the tool.
Open the blade clamp collar (7) to release the blade
clamping mechanism.
Insert the saw blade (8) into the holder (4) until it
engages. The blade can be installed with the teeth
pointing down or up.
Close the blade clamp collar (7) to lock the blade
clamping mechanism.
To remove the saw blade, proceed in reverse order.