3 Product description

2.4 Product safety

• The product has been developed and manufactured in accordance with state-of-the-art technology and the recognized
safety standards and regulations. These operating instructions warn you against unavoidable residual risks to users, third
parties, devices or other material property. Disregarding these warnings may result in risks to human life and health,
environmental damage or material damage.
• The product may only be operated in an unmodified, technically perfect condition, within the limits described in these
instructions.
• Always observe the limit values specified in the technical data. Overloads lead to destruction.
• Safety features on the device must never be disassembled, bridged or otherwise bypassed.
• During welding work outdoors, use suitable protection against the weather conditions.
• Check the electrical device for any damage and for proper functioning in accordance with its designated use.
• Never expose the electrical device to rain and avoid damp or wet environments.
• Protect yourself from electrical accidents by using insulating mats and wearing dry clothing.
• Never use the electrical device in areas subject to a risk of fire or explosion.
• Adhere to the general fire protection regulations and remove flammable materials from the vicinity of the welding work
area prior to starting work. Keep suitable fire extinguishing equipment at the workplace ready for use.
2.5 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
Further measures can be found in the operating instructions for the power source or the documentation of further peripheral
devices.
3 Product description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorization.
• The device may only be used by qualified personnel (in Germany, see TRBS 1203).

3.1 Technical data

Dimensions (lxwxh)
Weight
Connection cable length
Supply voltage
Current consumption
Protection type of panel front
Protection type of housing
Display
CPU
Tab. 1
MF Control remote control
EN - 4
270 × 247 × 90 mm
2.0 kg
10 m
24 VDC via the connection lead
650 mA
IP 65
IP 54
7-inch TFT with resistive touchscreen,
WVGA 800 × 480 pixels
Intel Atom 1.0 GHz E640T
BAL.0532.0 • 2018-08-16