1. Insert the included installation CD into CD-ROM drive and then follow the on-screen
instructions to proceed software installation. If there no screen shows 1 minute after
inserting the CD, please execute setup.exe file for initiating software installation.
2. Follow the on-screen instructions to install the software.
3. When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
2-5. Battery Replacement (Only for RT Models)
NOTICE: This UPS is equipped with internal batteries and user can replace the batteries
without shutting down the UPS or connected loads.(hot-swappable battery design)
Replacement is a safe procedure, isolated from electrical hazards.
CAUTION!! Consider all warnings, cautions, and notes before replacing batteries.
Note: Upon battery disconnection, equipment is not protected from power outages.
Step 1
Remove front panel.
Step 4
Remove the top cover of
battery box and replace the
inside batteries.
Step 7
LA-ON-1K/2K/3K-LCD/RACK-V.10 (2018)
Step 2
Disconnect battery wires.
Step 5
After replacing the
batteries, put the battery
box back to original location
and screw it tightly.
Put the front panel back to the unit.
9
Step 3
Pull out the battery box by
removing two screws on the
front panel.
Step 6
Re-connect the battery wires.