Operations; Button Operation; Lcd Panel - lapara LA-ON-1K-LCD-V.10 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Operations

3-1. Button operation

Button
Function
 Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to
turn on the UPS.
 Mute the alarm: After the UPS is turned on in battery mode, press and
hold this button for at least 3 seconds to disable or enable the alarm
ON/Mute
system. But it's not applied to the situations when warnings or errors
Button
occur.
 Up key: Press this button to display previous selection in UPS setting
mode.
 Switch to UPS self-test mode: Press ON/Mute buttons for 3 seconds to
enter UPS self-testing while in AC mode, ECO mode, or converter mode.
 Turn off the UPS: Press and hold this button at least 2 seconds to turn off
the UPS. UPS will be in standby mode under power normal or transfer to
OFF/Enter
Bypass mode if the Bypass enable setting by pressing this button.
Button
 Confirm selection key: Press this button to confirm selection in UPS
setting mode.
 Switch LCD message: Press this button to change the LCD message for
input voltage, input frequency, input current, battery voltage, battery
current, battery capacity, ambient temperature, output voltage, output
Select
frequency, load current and load percent.
Button
 Setting mode: Press and hold this button for 3 seconds to enter UPS
setting mode when Standby and Bypass mode.
 Down key: Press this button to display next selection in UPS setting
mode.
 Switch to bypass mode: When the main power is normal, press ON/Mute
and Select buttons simultaneously for 3 seconds. Then UPS will enter to
bypass mode. This action will be ineffective when the input voltage is out
ON/Mute
of acceptable range.
+ Select
 Exit setting mode or return to the upper menu: When working in setting
Button
mode, press ON/Mute and Select buttons simultaneously for 0.2 seconds
to return to the upper menu. If it's already in top menu, press these two
buttons at the same time to exit the setting mode.

3-2. LCD Panel

LA-ON-1K/2K/3K-LCD/RACK-V.10 (2018)
12

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido