5.2
Fitting the MX SM magazine
1. Insert the X-460-PSM piston and push it into the tool as far as it will go.
2. Fit the X-460-B buffer onto the MX SM magazine.
3. Push the magazine firmly onto the exhaust gas piston return unit.
4. Screw on the magazine firmly until it engages.
5.3
Loading the magazine tool
1. Make sure that the loading / unloading button is in line with the magazine.
2. From below, push the collated fasteners into the magazine as far as they will go.
3. Push the cartridge strip, narrow end first, into the grip of the tool from below until the full length of the
cartridge strip is inside the tool. If you wish to use a cartridge strip in which some of the cartridges have
already been used, start pulling the strip up and out the top of the tool by hand until the first unused
cartridge is in place in the cartridge chamber.
5.4
Setting the power level
1. Press the power regulator release button.
2. Turn the power regulating wheel to set the power level you require.
3. Check the quality of the fastening in accordance with Hilti standards.
Select a cartridge power level and power setting to suit the application.
If you have no previous experience of using the tool, always begin with the lowest power.
5.5
Driving fasteners with the magazine tool
1. Position the tool.
2. Hold the tool perpendicular to the working surface and then press it against the surface.
3. Press the trigger to drive the fastener.
5.6
Unloading the magazine tool
1. Pull the cartridges out of the tool.
2. To remove unused fasteners from the magazine, turn the loading / unloading button to a right angle
relative to the magazine.
◁ The collated fasteners can be removed.
3. If there are fasteners in the tool, remove them by twice pushing the pusher supplied for the purpose into
the hole above the magazine.
Use only the pusher supplied for the purpose, otherwise the magazine can be damaged.
4. Turn the loading/unloading button back to its initial position.
5.7
Switching Bluetooth on and off
▶ Press and hold the pushbutton for 1-2 seconds to switch on Bluetooth.
Bluetooth switches itself off automatically after 2 minutes.
5.8
Resetting the cleaning indicator
▶ Press and hold the pushbutton for 10-12 seconds to reset the cleaning indicator.
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
5.9
Procedure if a cartridge fails to fire
1. Keep the nose of the tool pressed at right angles against the working surface for 30 seconds.