10
Optional Installation
6. Check Flow
With the main drain closed, and one end of the hose attached to the vac port fitting installed in the dedicated
vacuum line, insert the flow gauge into the other end of the hose. Keep the hose and flow gauge
underwater. Turn on the pump. With the pump running, adjust the vacuum regulator (in your skimmer) until
the indicator on the flow gauge is between minimum and maximum flow (Figure 19). Remove the flow
gauge and proceed to step 7.
7. Connect Hose to the Cleaner's Swivel Assembly
Connect the large hose cuff (Figure 20) of the leader hose to the swivel assembly on the cleaner head.
Push the cleaner into the pool and let it sink to the bottom (Figure 21).
Figure 20
8. Turn the pool pump on
After completing the installation, turn the pool pump on and allow it to run for a couple of minutes to ensure
that all air cycles out of the system.
Great White Installation and User's Guide
(Continued)
Figure 19
Large hose cuff
of leader hose
designed to connect
to swivel assembly
(See "Hose Assembly"
on Page 3)
Disc Indicator
Figure 21