3.2.3: Pull the inner part of the bushing completely
out of the SRL housing.
3.2.4: Remove plastic cap on back cover with fl at
blade screw driver.
3.2.5: Remove plastic cap at top of SRL, near
pivoting anchorage loop.
3.2.6: Using a 1/8 inch Allen wrench, remove set
screw on the SRL cover.
3.2.7: With gloved hand, pull the entire lifeline out
of the SRL housing, including the lifeline reserve.
THE BEGINNING OF THE LIFELINE RESERVE
IS IDENTIFIED BY THE METAL MARKER (A) ON
THE LIFELINE. THE LIFELINE RESERVE LENGTH
IS APPROXIMATELY 18 INCHES (46 CM),
FROM THE METAL MARKER TO THE END OF THE
LIFELINE.
CAUTION:
There is signifi cant tension on the lifeline.
Maintain lifeline control at all times. Do not release lifeline
until Step 3.2.8 is completed. When pulling lifeline out,
SRL can be secured to a work bench or other object to
keep SRL in place.