OBJ_BUCH-0000000289-001.book Page 10 Wednesday, November 22, 2017 8:24 AM
en
10
Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
Sound emission
A-weighted emission pressure power
level measured at the workplace
20 μPa), in decibels
K
Measuring uncertainty
Measured A-weighted sound power level
L
(re 1 pW), in decibels
wA
Measuring uncertainty
K
C-weighted peak sound pressure level
measured at the workplace
decibels
Measuring uncertainty
K
Vibrations
(Ø 25 mm)
Mean vibrational value for surface grinding
with straight grinder
, in
h,SG
2
– m/s
2
– ft/s
(Ø 50 mm)
Mean vibrational value for surface grinding
with straight grinder
, in
h,SG
2
– m/s
2
– ft/s
Mean vibrational value for polishing with
straight grinder
, in
h,P
2
– m/s
2
– ft/s
K
Measuring uncertainty
2
– m/s
2
– ft/s
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
AGSZ18-280 BL
L
(re
pA
, in decibels
pA
, in decibels
wA
L
, in
pCpeak
, in decibels
pCpeak
, in
AGSZ18-280 LBL
AGSZ18-90 LBL
(**)
(**)
84
85
3
3
95
96
3
3
98
98
3
3
5.0
5.0
16.4
16.4
12.0
12.0
39.4
39.4
–
–
–
–
1.5
1.5
4.9
4.9
(**)
85
3
96
3
98
3
1.0
3.3
2.0
6.6
3.0
9.8
1.5
4.9