L1 → 1/L1
L2 → 3/L2
L3 → 5/L3
1L1
2T1
2/T1 → U
4/T2 → V
6/T3 → W
1L1, 3L2, 5L3, 2T1, 4T2, 6T3, +A1/A2, 13/14, 23/24, +U
2
2
mm
mm
Power
0.75 - 16
0.75 - 16
2 x 0.75 - 10
2 x 0.75 - 10
Control
0.5 - 2.5
0.5 - 1.5
2 x 0.5 - 1.0
2 x 0.5 - 0.75
10
20
t-Start (s)
1
30
U-Start (%)
30
100
10
20
t-Stop (s)
0
30
Uc, Us
+A
13 14
DS7-340…
24 V AC/DC
1 A, 24 V AC/DC,
50/60 Hz
DS7-342…
230 V AC
1 A, 230 V AC 11,
50/60 Hz
DS7-34D…
24 V DC
1 A, 24 V DC
6/8
3L2
5L3
4T2
6T3
+U
-U
S
S
....A
-U
s/
s
UL-use
AWG
mm
in
18 - 6
10
0.39
10
0.39
18 - 14
6
0.24
2 x 18 - 16
6
0.24
U
5 s
U
LN
30 % U
LN
0 s = OFF
U-Start
TOR
RUN
+A1
23 24
RUN
23 24
TOR
RUN
+A1
-A2
13
14
23
2
mm
AWG
Nm
1 x 6
PZ2
3.2
1 x 6
PZ2
3.2
0.6 x 3.5
0.6
0.6 x 3.5
0.6
t-Start
TOR
TOR
13 -A2
13 -A2
(Top Of Ramp)
RUN
23 24
Emergency On Call Service: Local representative
USA: EatonCare at
24
lb-in
28.32
28.32
5.31
5.31
t
t-Stop
TOR
13 -A2
Eaton.eu/aftersales
or +49 (0) 180 5 223822 (de, en)
Eaton.com/eatoncare
or 877-386-2273
I
= 20 mA
c
① I
= 30 mA + [I
]
s
FAN
② I
= 100 mA + [I
]
s
FAN
I
∼ 250 mA, 50 ms
Peak
I
= 50 mA
FAN

Publicidad

loading

Este manual también es adecuado para: