Fault
Cause of fault
No voltage present
Power pack overloaded
Receiver overloaded
Lighting flashes
Receiver overloaded
or flickers.
Power pack overloaded
Cable connections are
not firmly connected.
Different light
Connections mixed up
colours.
Line circuit
Power pack defective
breaker
triggers.
11 Repair
Due to the design, a LIPROTEC component cannot be repaired.
If a component is defective or losing power, you can have it replaced with a new one.
Follow the instructions provided in the chapters entitled "Decommissioning", "Mounting"
and "Commissioning" during this process.
Directions for use for LED strips
Remedy
Have a qualified electrician check and, if
necessary, repair the power pack's mains
cable and the socket.
Select a larger power pack (up to max.
200 W).
Check the maximum load of the respective
connections on the receiver. The LED strips
may have to be distributed differently over
the respective connections (observe the
respective connections' maximum load).
Check the maximum load of the respective
connections on the receiver. The LED strips
may have to be distributed differently over
the respective connections (observe the
respective connections' maximum load).
Select a larger power pack (up to max.
200 W).
Check the cable connections for non-
positive locking.
Check that all of the cable connections are
connected properly. Test the colours red,
green and blue. Test the warm white to
daylight white colour temperature.
Replace the power pack.
EN
Repair
35