Brush Contact Control
when the handle is lowered, slide the transport/working
mode knob up one step.
Cleaning Liquid Discharge Control
Pull cable connect / disconnect control
Motor Overload Protector
the protector button after minimum of 30 seconds from
tripping by pressing the over load protector manually and
continue working.
IMPORTANT - Should the machine fail to operate, contact
the supplier from whom you purchased the machine.
4. Operation
Brush contact with the floor
is adjustable in 4 steps,
contact is MINIMUM when
the knob is fully down and
MAXIMUM when it is fully
raised. This helps you to
compensate for the wear of
brushes and also to control
the scrubbing effect. If the
machine does not move
By
pulling,
the
discharge control handle
up, the cleaning solution is
dispensed on the floor. The
solution stops once the
liquid
discharge
control
handle is released.
Insert the free end of pull
cable into the valve body
fitted in the fresh water
tank.
Press
and
clockwise to secure the
cable end. Similarly, press
and twist anti clockwise to
disconnect the cable end.
In the event of motor
getting overloaded due to
improper power supply or
unexpected obstruction to
the brush/drum rotation,
the over load protector
trips
and
protects
motor from damage. If this
happens,
identify
cause, correct it and, reset
4.1 Checks before use
• Ensure that the brushes
are fitted properly
• Fill fresh water tank with
cleaning solution
• Insert the plug into mains socket
4.2 Using the machine
WARNING - Never start the machine without a brush or
pad fitted.
Recommended washing sequence
liquid
twist
1. Start the machine by pressing the pedal and pulling the
handle back (Fig-ii).
the
2. Move forward, while sparingly pulling the liquid
discharge control handle (Fig-iii). This handle should
the
not be kept pulled all the time. The duration and
frequency of pulling and releasing has to be adjusted
to match with the type of floor, extent of dirt. etc. For
tiled or stone floors, apply very little water. The spray
pattern of the Multiwash can be adjusted by the user.
Adjust the spray to prevent solution being dispensed
onto areas that already have been cleaned. The spray
pattern is adjusted by using the serrations in the spray
nozzle and holder. Each serration allows a 4 degree
change (Fig-i v).
3. Stop the liquid discharge approximately 30 cm before
the end of forward motion, continue to move forward
up to the wall without pulling the pull handle.
4. Pull the machine backwards in the same track, but
without discharging any liquid. When you reach the
starting point, change the track and repeat steps 2
through
6