3. Set the rotary switch to an appropriate
measurement position in A
measurement is default or press SELECT button
to select DC measurement mode.
4. Break the current path to be tested. Connect
the red test lead to the more positive side of
the break and the black test lead to the more
negative side of the break.
5. Turn on power to the circuit. The
measured value shows on the display.
Note:
• If the value of current
to
be
measured
unknown,
use
the
maximum measurement
position
(10A)
and
reduce
the
range step by step
until a satisfactory
reading is obtained.
range. DC
Figure 4
is
• When current measurement has been completed,
disconnect the connection between the testing
leads and the circuit under test.
D.
AC Current Measurement
Never attempt an in-circuit
current measurement where the
open-circuit voltage between
the circuit and ground is greater
than 500V. If the fuse burns
out during measurement, the
Meter may be damaged or the
operator himself may be hurt.
Use proper terminals function,
and range for the measurement.
When the testing leads are
connected to the current
terminals, do not parallel them
across any circuit.
E N G L I S H
(Figure 4)
Warning
31