Use charging converter
10
Use charging converter
10.1
Switch charging converter on/off
The charging converter turns on automatically as soon as it receives a positive control
signal. The status LED glows blue.
The charging converter switches off automatically when the control signal is no
longer present.
I
NOTE
If the control signal of the charging converter is switched via the ignition,
the starter battery can discharge if the engine is not started in a timely
manner.
10.2
Adjust charging converter
I
NOTE
Take the values for the charging end voltage and maintenance charge
voltage of your battery from the battery manufacturer's specifications.
You can adjust the device using the DIP switch (fig. 1 7, page 3).
Set switchover voltage/constant voltage
You can use the DIP switches S1 and S2 to set the value of the end-of-charge voltage.
S1
ON
OFF
ON
OFF
20
Switchover voltage/constant voltage
S2
ON
ON
OFF
OFF
12 V
14.4 V
14.1 V
14.7 V
PerfectCharge
24 V
28.8 V
28.2 V
29.4 V
EN